Brand: Fluke

FLUKE 437-II Three-phase Power Quality Analyzer

Product Code: 560437-II

Inventory Status: discontinued

FLUKE 437-II Three-phase Power Quality Analyzer

The new Series 430 II Power Quality and Energy Analyzers offer the best in three-phase power quality analysis and introduce, for the first time, the ability to quantify energy losses in monetary terms. The new Fluke 434, 435 and 437 II Series models help locate, predict, prevent and solve power quality problems in three-phase and single-phase power distribution systems. In addition, Fluke's patented Unified Power Measurement algorithm measures and quantifies energy losses due to harmonic and imbalance problems, allowing the user to identify the source of the waste. of energy in an electrical distribution system.

  • Energy loss calculator: classic measurements of active and reactive power, as well as unbalance power and harmonics are quantified to identify the true energy losses of the system expressed in euros (other local currencies available).
  • Power Inverter Efficiency: Simultaneous measurement of AC output power and DC input power for power electronic systems, using optional DC clamps.
  • PowerWave Data Acquisition: Series 435 and 437 II analyzers quickly acquire RMS data, show half cycle and waveforms to characterize electrical system dynamics (generator starts, UPS switching, etc.).
  • Waveform Acquisition: The 435 and 437 Series II models capture 100/120 cycles (50 / 60Hz) of each event that is detected in all models, with no configuration required.
  • Auto Transient Mode: The 435 and 437 Series II analyzers capture waveform data at 200 kHz on all phases at the same time up to 6 kV.
  • Full Class A Compliance: The 435 and 437 Series II analyzers perform tests to the most stringent international standards, IEC 61000-4-30 Class A.
  • Signal transmission: 435 and 437 Series II analyzers measure interference due to oscillation control signals at specific frequencies
  • 400 Hz Measurement: The 437 Series II analyzer captures power quality measurements in the aviation and military industries .
  • Problem solving in real time: Trend analysis using the cursor and zoom tools.
  • The highest safety class in the industry: 600 V CAT IV / 1000 V CAT III for use at the connection point.
  • Measurement of all three phases and neutral: with the four flexible current probes included, with iFlex technology specifically designed to adapt to the tightest and most confined spaces.
  • Auto Trend Detection: Each measurement is always automatically logged, with no configuration required.
  • System-Monitor : ten power quality parameters on one screen in accordance with EN50160 power quality standards.
  • Logging Function: Configurable for any test condition with memory that can hold up to 600 parameters at user defined intervals.
  • Visualization of graphs and generation of reports: with analysis software included.
  • Battery life: seven hours of operation, per charge, with the lithium ion battery.

UNIFIED MEASUREMENT OF POWER

Previously, only scholars could calculate how much energy was wasted due to power quality problems; utilities could calculate the cost, but the necessary metering process was beyond the reach of the average electrician. With the new patented unified power measurement feature available on the 430 Series II analyzers, you have a portable instrument to determine how much power is being wasted and
calculate the respective cost exactly. The Unified Power Measurement System (UPM) offers the most comprehensive view of available power by measuring:

  • Parameters of classical power (Steinmetz 1897) and IEEE 1459-2000 power
  • Detailed loss analysis
  • Analysis of imbalances

UPM calculations are used to monetize the energy loss caused by power quality problems. The calculations are performed, along with other facility-specific data, via an Energy Loss Calculator which ultimately determines how much money a facility loses due to wasted energy.

LOGGER: POSSIBILITY 'OF THE RECORD T U TTE INFORM provisions necessary

User configurable, long-term logging of MIN, MAX and AVG (average) readings for up to 150 parameters across all 4 phases. The memory is sufficient to record 600 parameters for more than a year with a resolution of 10 seconds or to capture smaller variations with a resolution of up to 0.25 seconds. The logging function is quickly accessible using the LOGGER button. The guided configuration makes it extremely easy to acquire important measurements.

MEASURES FOR EVERY NEED


Measure true RMS values, peak current and voltage, frequency, dips and swings, transients, interruptions, power and electricity consumption, absorption peaks, harmonics up to 50th, inter -harmonics, flicker, network signaling, inrush current and imbalances.

POWERLOG SOFTWARE

With Power Log software, you'll have reports and graphs at your fingertips. Designed to quickly view logged data, the Power Log software included in these tools allows you to view all logged parameters on interactive trends. Generate a professional report with the "Report Writer" function or manually copy and paste images into the report.

  • View recorded data in simple graphs and tables.
  • Customize the reports by selecting the period and measures to include.
  • Create professional reports quickly and easily.

Other characteristics

The measurements can be combined with the wiring under examination by changing the colors of the traces on the large color display.
The oscilloscope display shows current and voltage waveforms for all three phases. It is possible to switch to a phase diagram at any time.
The phase diagram shows the voltage and current imbalances and makes it easier to check the connections.
Recording of changes shorter than a half cycle, with readings of the minimum, maximum and average values.
Up to the 50th harmonic can be displayed and total harmonic distortion can be measured and recorded according to the requirements of the IEC61000-4-7 standard.
Inrush current measurement highlights the starting current of motors and other devices to help identify critical values.

COMPARISON OF CHARACTERISTICS

BC430 adapter ACCESSORIES SUPPLIED

  • Universal plug adapter
  • BP290 (single capacity Li-ion battery) 28 Wh (7 hours or more)
  • Set of TL430 test leads and alligator clips
  • WC100 color coded tweezers and typical decals
  • i430flex-TF, 24 inches (61 cm) length, 4 grippers
  • 8GB SD card
  • PowerLog on CD (includes PDF user manuals)
  • USB AB mini cable

ElcoBlog Vedi tutte le news

Elco Elettronica diventa distributore ufficiale e partner di Powerside

Elco Elettronica distributore Powerside

Elco Elettronica è diventata distributore ufficiale e partner di Powerside, leader mondiale nel settore della qualità dell'energia elettrica e delle soluzioni per il monitoraggio dell'energia.

Leggi tutto
Blog Summer Break 2024

Agosto 2024 - Summer Break

Chiusura Estiva? Relax per Noi, Risparmio per Voi!

Leggi tutto
Fluke BAFGAFF 2024

Acquista un prodotto Fluke e ne ottieni uno GRATIS!

Ritorna la promozione "Acquista un prodotto Fluke e ne ottieni uno GRATIS"

Leggi tutto
Blof Problemi Ricezione TV Digitale Terrestre Estate

Digitale terrestre in Veneto: risolto il problema della ricezione dei canali Rai?

Un problema che affligge da tempo i cittadini di una vasta area del Veneto, da Treviso a Jesolo, fino a Portogruaro, sembra essere finalmente in via di risoluzione.

Leggi tutto

Icona con box
Oltre 65.000 prodotti 
di elettronica professionale 
in pronta consegna.
Icona qualità certificazione iso9001 2015
Elevata qualità garantita 
dal sistema di gestione 
della qualità ISO9001 2015
Icona spedizioni rapide
Consegne Rapide
in 24 - 48 ore su tutto
il territorio nazionale.
Icona monitor pc
Abilitazione per il mercato
elettronico della pubblica
amministrazione MEPA / SIAC