WCB2 Weller calibration and measurement unit
Product Code: 560WCB2
WCB2 Weller calibration and measurement unit
The WCB2 is an external programming or calibration unit for activating or deactivating additional functions. It is compatible with any Weller digital drive (except WMD 3). Setting it up is quick and easy. The battery power supply makes it independent from the mains and easy to transport. The WCB2 is equipped with an RS 232 interface socket for the PC and also integrates the function of digital thermometer combined with a type K probe (accessory).
The functions are:
- OFFSET: Correction of the sealing thermal delta after a thermal check of the tip temperature
- SETBACK: Automatic temperature reduction to 150 ° C
- LOCK: Lock of the temperature selection
- ° C / ° F: display in ° C or ° F
- Temperature range window. If the temperature falls within the programmed range, a potential-free contact is activated
- Calibration tips are available for any soldering stylus
WCB2 Calibration unit consists of:
- Calibration unit
- 4 x 1.5V batteries
Accessories:
- T0053118499 Mains adapter 230 V, 50 Hz for WCB2
- T0053119099 Thermocouple type K Ø 0,5 mm
- T0053119199 RS 232 interface cable